Harvia The Wall Combi SW70S Bastuaggregat stål 7 kWHarvia The Wall Combi SW45S Bastuaggregat stål

Før du bestiller
- StrømTilsluttes fast af en autoriseret elinstallatør, sikring 10 A.
- PladsSaunarummet skal være mindst 190 cm højt.
Mål og tal
Kan tilsluttes 1 faseJa
Fuses (400V3N~) pcs x ampers: 3 x 10 A; Fuse (230V1N~) ampers: 25 A
Kabel1,5 mm²
Supply cable (400V 3N~) mm2: 5 x 1.5 mm2
Stenstørrelse5-10 cm
Stone sizes: Ø5–10 cm
StyringEkstern
Control type: Controlled by a separate control unit
Styring med i prisenNej
Control type: Controlled by a separate control unit
StyringstypeEkstern
Control type: Controlled by a separate control unit
Mål71 x 38 x 35,5 cm
Product height: 710 MILLIMETER; Product width: 380 MILLIMETER; Product depth (mm): 355 MILLIMETER
Vægt16 kg
Net weight (kg): 16 KILOGRAM
MonteringVæg
Installation location: Wall
MaterialeRustfrit stål
Main material: Steel; Color: Stainless Steel
IP-klasseIPX4
IP Class (like: IPX4): IPX4
AnvendelseHjem
User group: Households
Producentens typekodeSW45S
Type code: SW45S (HSW450400S)
Tilslutning (sikring og kabel)400 V 3N~: sikring 3 x 10 A, kabel 5 x 1.5 mm2 · 230 V 1N~: sikring 25 A
Fuses (400V3N~) pcs x ampers: 3 x 10 A; Supply cable (400V 3N~) mm2: 5 x 1.5 mm2; Fuse (230V1N~) ampers: 25 A
Med i prisen og nødvendige tilkøbSten skal købes for sig, Styring skal købes for sig
Content of delivery (listed): Heater | Installation bracket | Installation and operating instructions | Stone cup; Control type: Controlled by a separate control unit
SikkerhedsafstandeLoft 1200 mm, foran 20 mm, foran (brændbart) 20 mm, side 35 mm, side (brændbart) 35 mm, venstre side (brændbart) 35 mm, højre side (brændbart) 35 mm, bag 0 mm, bag (brændbart) 0 mm, gulv ved 1 fase 80 mm, gulv ved 3 faser 80 mm
Safety distance (Ceiling): 1200 MILLIMETER; Safety distance front (non-combustible materials): 20 MILLIMETER; Safety distance front (combustible materials): 20 MILLIMETER; Safety distance side (non-combustible materials): 35 MILLIMETER; safety distance to the side wall (combustible materials): 35 MILLIMETER; Safety distance left side (combustible materials): 35 MILLIMETER; Safety distance right side (combustible materials): 35 MILLIMETER; Safety distance behind (non-combustible materials): 0 MILLIMETER; Safety distance behind (combustible materials): 0 MILLIMETER; Safety distance (Floor 1ph) (depends on connections and therefore from output, star/delta): 80 MILLIMETER; Safety distance (Floor 3ph) (depends on connections and therefore from output, star/delta): 80 MILLIMETER
Andre kombiovne
Harvia The Wall Combi SW70S Bastuaggregat stål 7 kW